Commercial Series

Models produce from 4,500 to 14,400 gallons of water per day. Reduce heavy metals, nitrates, radionuclides, herbicides, pesticides, THM’s, VOC’s and other contaminants.

SSC Model

Features

  • RO Elements: 4″ x 40″ Extra Low Energy Thin Film
  • Pressure Vessels: 304 Stainless Steel (SS)
  • Pump: Centrifugal 304 SS Shell, 316 SS Shaft
  • Frame: 409 SS
  • Control: Programmable with LCD Readout
  • Flow Meters: Product and Waste
  • RO Pressure Gauges
  • Low Pressure Cutoff Switch
  • Pre Filter: 5 Micron Sediment
  • Inlet Filter Gauges (pre and post filter)
  • Inlet Feed Electric Solenoid Valve
  • Inlet Manual Shutoff Valve
  • Product Reverse Flow Check Valve
  • Waste Recycle Valve

Options

  • Total Dissolved Solids (TDS) Meter
  • Product Dump Valves (option requires TDS meter)
  • Remote System Status Indicator Lights
  • Carbon Tank for Chlorine Removal
  • Water Softener
  • UV Light
SCC Model Commercial Water

Dimensions

HeightDepthWidth
72 inches18 inches48 inches

Specifications

MembranesProduction*RecoveryMotor**Weight (Approx.)Inlet***Outlets
Qty. 34,500 GPD50%2 HP350 Lbs.1″ FNPT3/4″ FNPT
Qty. 46,000 GPD50%2 HP380 Lbs.1″ FNPT3/4″ FNPT
Qty. 5 7,200 GPD50%2 HP410 Lbs.1″ FNPT3/4″ FNPT
Qty. 69,000 GPD50%2 HP440 Lbs.1″ FNPT3/4″ FNPT
Qty. 812,000 GPD50%2 HP500 Lbs.1″ FNPT3/4″ FNPT
Qty. 10****14,400 GPD50% 2 HP 560 Lbs.1″ FNPT3/4″ FNPT

* Approximate product flow based on properly pretreated feed water of 1000 ppm TDS (as NACL), 15°C (59°F) and silt density index less than 3. Production capacity may vary due to feed water temperature, pressure, quality and product back pressure.

** Electrical: Standard: 230 VAC 60 HZ single phase (20 AMP L6-20 plug), Or 220/230 VAC 50 HZ Single Phase Pump: 125 PSI Maximum.
Important: do not operate at low or reduced voltage, (ie 208 VAC). Overheating and reduced pump life will occur.

*** Inlet pressure 20 PSI Minimum (when running), 80 PSI Maximum.

**** Qty. 10 available on 60 HZ units only (50 HZ not available).

Literature

CWM Model

Features

  • RO Element: 4″ x 40″ Extra Low Energy Thin Film
  • Pressure Vessels: 304 Stainless Steel (SS)
  • Pump: Centrifugal 304 SS Shell 316 SS Shaft
  • Frame: 409 SS
  • Flow Meters: Product And Waste
  • Low Pressure Cutoff Switch
  • Pre Filter: 1 Micron Sediment
  • Pump Inlet Pressure Gauge
  • Inlet Feed Electric Solenoid Valve
  • Inlet Manual Shutoff Valve
  • Product Reverse Flow Check Valve
  • Waste Recycle Valve
  • Electronic Controller

Options

  • Carbon Tank for Chlorine Removal
  • Water Softener
  • UV Light
  • Remote Storage Tank
  • Product Dump Valves
  • Remote Light Kit
  • Product Total Dissolved Solids (TDS) Meter
CWM Commercial Coster

Dimensions

HeightDepthWidth
72 inches20 inches30 inches

Specifications

ModelElementsProduction*RecoveryMotor**Shipping
Weight
(Approx.)
Inlet***Outlets
Product
Outlets
Concentrate
CWM-1Qty. 11,500 GPD50%3/4 HP200 Lbs.3/4″ FNPT1/2″ FNPT1/2″ FNPT
CWM-2Qty. 23,000 GPD50%3/4 HP230 Lbs.3/4″ FNPT1/2″ FNPT1/2″ FNPT

* Approximate product flow based on properly pretreated feed water of 1000 ppm TDS (as NACL), 15°C (59°F) and silt density index less than 3. Production capacity may vary due to feed water temperature, pressure, quality and product back pressure.

** Electrical: Standard: 240 VAC 60 HZ Single Phase Pump: (15 Amp Type 6-15P Plug), 125 PSI Maximum (4″ Element).
Optional: 240 VAC 50 Hz (Plug varies depending on location).

*** Inlet Pressure: 20 PSI Minimum (when running), 80 PSI Maximum.

Literature

EWM Model

Features

  • RO Elements: Extra Low Energy Thin Film
  • Pressure Vessels: 304 Stainless Steel (SS)
  • Frame: 409 SS
  • Pump: Vane type
  • Pump Pressure Gauge (liquid filled)
  • Low Pressure Cutoff Switch
  • Pre Filter: 1 Micron Sediment
  • Inlet Filter Gauge
  • Inlet Feed Electric Solenoid Valve
  • Inlet Manual Shutoff Valve
  • Product Reverse Flow Check Valve
  • Waste Recycle Valve

Options

  • Product Total Dissolved Solids (TDS) Meter
  • Float Shutoff Kit
Wall Mount Coster Engineering

Dimensions

HeightDepthWidth
50 inches7 inches24 inches

Specifications

ElementsProduction*RecoveryMotor**Weight (Approx.)
Inlet***
Outlets
Qty. 1 (4″)1,500 GPD50%1/2 HP120 Lbs.1/2″ FNPT3/8″ JG
Qty. 1 (2 1/2″)750 GPD50%1/2 HP110 Lbs.1/2″ FNPT3/8″ JG

* Approximate product flow based on properly pretreated feed water of 1000 ppm TDS (as NACL), 15° C (59° F) and silt density index less than 3. Production capacity may vary due to feed water temperature, pressure, quality and product back pressure.

** Electrical: Standard 120 VAC 60 HZ Single Phase

*** Inlet Pressure: 20 PSI Minimum (when running), 80 PSI Maximum.

Literature